11KV Drop Out Surge Arrester Product Overview:
In the event of a diverter failure, the ground lead disconnector (GLD) operates to ensure network safety through a highly efficient sequential isolation process:
- Automatic Disconnection: The failed Drop Out Surge Arrester drops out, disconnecting itself automatically from the active network.
- Phase Isolation: Simultaneously, this action forces the fuse expulsion pole mounted 11kv carrier to drop out, effectively isolating the affected phase.
- Interlocking Safety: A built-in interlocking mechanism ensures that it is not possible to close the fuse carrier unless the arrester is safely in the closed position.
Key Features of the Drop Out Surge Arrester:
Integrating this Drop Out Surge Arrester into your electrical infrastructure offers excellent stability and efficiency backed by reliable manufacturing standards:
- Operational Benefits: Improves overall system stability, ensures high security, offers convenient maintenance, and reduces costs.
- Certified Quality: Manufactured in ISO 9001, ISO 14001, and ISO 18001 certified facilities backed by a full set quality control plan.
- B2B Flexibility: Minimum Order Quantity (MOQ) is 100 pieces. Free samples are provided (freight excluded).
- Tender & EPC Support: Full sets of documents are ready for tender submissions. Strong design teams are available to supply LV and MV EPC material in lots.
- Customization: OEM services are readily available for custom requirements.
Drop Out Surge Arrester Applications:
The combined Drop Out Surge Arrester is built specifically for reliable high-voltage distribution network protection.
- Automatic Phase Isolation: Protects the network by automatically isolating affected phases during surge diverter failures.
- Distribution Networks: Functions as a reliable 11kv surge arrester for power networks requiring an integrated, fail-safe interlocking protective mechanism.
Drop Out Surge Arrester 11 KV Technical Specifications:
Review the exact electrical parameters below to ensure this Drop Out Surge Arrester meets your system requirements.
General System Parameters:
| Technical Parameter | Specification Details |
|---|---|
| System Highest Voltage & Frequency | 12kV, 50Hz |
| Creepage Distance | 372 mm |
| Lightning Impulse Withstand Voltage | 95 kV |
| Power Frequency Withstand Voltage (Wet) | 38 kV |
Surge Arrester Parameters:
| Technical Parameter | Specification Details |
|---|---|
| Maximum System Voltage | 12 kV |
| Rated Voltage | 11 kV |
| Partial Discharge Performance | < 10 |
| Power Frequency Withstand Voltage (1 min, Wet) | 46 kV |
| Max Residual Voltage (Steep, Lightning, Switching) | 31.9 kV |
DIMENSION: